Newly Arrival 33kv Voltage Transformer - KYN61-40.5(z)high voltage armored Removable Ac Metal-enclosed Switchgear – Pengbian
Newly Arrival 33kv Voltage Transformer - KYN61-40.5(z)high voltage armored Removable Ac Metal-enclosed Switchgear – Pengbian Detail:
Product Description
KYN61-40.5 air-insulated metal-clad withdrawable switchgear (hereinafter as switchgear is a kind of MV switchgea r.
It is designed as a withdrawable module type panel, and the withdrawable part is fitted with VD4-36E,VD4-36 withdrawable vacuum circuit breaker,It can also be fitted with isolation truck, PT truck, fuses truck and so on. It is applicable to three phase AC 50/60 Hz power system
KYN61-40.5 armored metal-enclosed switchgear (switchgear for short) is a switchgear designed and improved by our factory on the basis of the original product. It is suitable for three-phase AC 50Hz power system, used for receiving and distributing electric energy and controlling, protecting and monitoring the circuit.
This switchgear has various functions to prevent misoperation, including preventing the load from moving the handcart, preventing the live connection of the grounding switch, and preventing the charging of the live interval.
This switchgear is equipped with excellent ZN85, VN1 vacuum circuit breakers or ABB’s VD4, HD4 series vacuum circuit breakers. Switchgear is a power distribution equipment with advanced technology, stable performance, reasonable structure, convenient use, safe and reliable.
Model meaning
MODEL:KYN61-40.5 □ □ □ |
K: Metal armored |
Y: move away | |
N: Indoor | |
61: Design serial number | |
40.5: Rated voltage (kV) | |
□: Circuit breaker type Z vacuum SF6 sulfur hexafluoride | |
□: Rated current | |
□: Rated short-circuit breaking current (kA) |
Main Feature
•The cabinet body is made of aluminum-zinc-coated sheets processed by numerical control equipment, and then spliced by bolts or willows. The structure is fully assembled.
• It can be equipped with ZN85-40.5 vacuum circuit breaker handcart, VN1, VD4 or HD4 vacuum circuit breaker handcart at the same time, and the main busbar of the switch cabinet is through without transition cabinet transfer.
• There is ample space in the cable room, and the air gap between phases can be guaranteed to be greater than 300mm, and there is no need to install insulating partitions between phases.
Service environment
Normal Operating Conditions
A. Ambient temperature: -15 40
B. Ambient humidity:
Daily average RH no more than 95%;Monthly average RH no more than 90%
Daily average value of the steam pressure no more than 2.2k Pa, and montly no more than 1.8kPa
C. Altitude no higher than 1000m;
D. The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog;
E. External vibration from switchgear and controlgear or land quiver can be neglected;
F. The voltage of the secondary electromagnetism interference induced in the system shall no more than 1.6kV.
Special Operating Conditions
According to IEC60694, GB/T11022, the manufacturer and user may agree on special service conditions whic hdeviate from the normal service conditions.
To prevent the condensation phenomena,the heater is necessary for switchgear and needs to be put into service
when the switchg ear is in readiness and service conditons. The heat dissipation probl em of switchg ear can be sloved by ventilation facilities.
Product Paramenters
Main technical parameters of switchgear
project
|
unit
|
parameter
|
||
Rated voltage
|
kV
|
40.5
|
||
Rated insulation level
|
1 min power frequency withstand voltage (effective value)
|
kV
|
Meet and face 95
|
Isolation fracture 118
|
Lightning impulse withstand voltage (peak value)
|
kV
|
185
|
215
|
|
One minute power frequency withstand voltage of auxiliary control circuit
|
V
|
2000
|
||
Rated frequency
|
Hz
|
50/60
|
||
Rated current
|
A
|
1250、1600、2000
|
||
Rated short-circuit breaking current
|
kA
|
20、25、31.5
|
||
Rated short-circuit making current (peak value)
|
kA
|
50、63、80
|
||
Rated short-time withstand current (4s)
|
kA
|
20、21.5、31.5
|
||
Rated peak withstand current
|
kA
|
50、60、80
|
||
Rated voltage of auxiliary control circuit
|
V
|
-100、-220、-220
|
Technical parameters of ZN85-40.5 vacuum circuit breaker
project
|
unit
|
parameter
|
|||
Rated voltage
|
kV
|
40.5
|
|||
Rated insulation level
|
power frequency withstand voltage (effective value)
|
kV
|
95
|
||
Lightning impulse withstand voltage (peak value)
|
kV
|
185
|
|||
Rated frequency
|
Hz
|
50
|
|||
Rated current
|
A
|
630,1250、1600、2000
|
|||
Rated short-circuit breaking current
|
kA
|
20、25、31.5
|
|||
Rated short-circuit making current (peak value)
|
kA
|
50、63、80
|
|||
Rated short-time withstand current (4s)
|
kA
|
20、25、31.5
|
|||
Rated peak withstand current
|
kA
|
50、63、80
|
|||
Rated capacitor bank breaking current
|
A
|
630/400
|
|||
Breaking times of rated short circuit breaking current
|
Times
|
20
|
|||
Rated operation sequence
|
O-0.3s-CO-180s-CO
|
||||
Opening time
|
ms
|
20-60
|
|||
Closing time
|
ms
|
40-100
|
|||
Mechanical time
|
Times
|
10000
|
Product detail pictures:
Related Product Guide:
Cooperation
The consumer fulfillment is our primary goal. We uphold a consistent level of professionalism, top quality, credibility and service for Newly Arrival 33kv Voltage Transformer - KYN61-40.5(z)high voltage armored Removable Ac Metal-enclosed Switchgear – Pengbian , The product will supply to all over the world, such as: Tunisia , Canada , Surabaya , So that you can utilize the resource from the expanding info in international trade, we welcome shoppers from everywhere on-line and offline. In spite of the good quality solutions we offer, effective and satisfying consultation service is supplied by our specialist after-sale service team. Product lists and detailed parameters and any other info weil be sent to you timely for your inquiries. So please make contact with us by sending us emails or call us if you have any questions about our corporation. ou may also get our address info from our web page and come to our company to get a field survey of our merchandise. We are confident that we are going to share mutual achievement and create strong co-operation relations with our companions in this marketplace. We're searching forward for your inquiries.
By Christine from Chile - 2018.02.08 16:45
The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
By Christopher Mabey from Pakistan - 2018.11.11 19:52