S13-M series 10 kv three-phase double winding excitation regulating distribution transformer
Rated capacity(kVA) |
Voltage Combinationand Tap range |
Vector Group Symbol |
No-load loss (W) |
Load loss |
No-load current (%) |
Short circuit impedance (%) 4.0 |
||
High pressure |
High pressure tap range (%) |
Low ressure (kV) |
||||||
30 |
6 6.3 6.6 10 10.5 11 |
±2×2.5 ±5 |
0.4 |
Dyn11 Yzn11 Yyno |
80 |
630/660 |
1.2 |
4.0 |
50 |
100 |
910/870 |
1.0 |
|||||
63 |
110 |
1090/1040 |
0.95 |
|||||
80 |
130 |
1310/1250 |
0.95 |
|||||
100 |
150 |
1580/1500 |
0.90 |
|||||
125 |
170 |
1890/1800 |
0.90 |
|||||
160 |
200 |
2310/2200 |
0.80 |
|||||
200 |
240 |
2730/2600 |
0.80 |
|||||
250 |
290 |
3200/3050 |
0.70 |
|||||
315 |
340 |
3830/3650 |
0.70 |
|||||
400 |
410 |
4520/4300 |
0.65 |
|||||
500 |
480 |
5410/5150 |
0.65 |
|||||
630 |
Dyn11 Yyno |
570 |
6200 |
0.45 |
4.5 |
|||
800 |
700 |
7500 |
0.45 |
|||||
1000 |
830 |
10300 |
0.45 |
|||||
1250 |
970 |
12000 |
0.40 |
|||||
1600 |
1170 |
14500 |
0.40 |
|||||
2000 |
1550 |
18300 |
0.30 |
5.0 |
||||
2500 |
1830 |
21200 |
0.30 |
e: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
S13-M series of 20 kv three-phase double winding non-field excitation changer distribution transformer
Rated capacity(kVA) |
Voltage Combinationand Tap range |
Vector Group Symbol |
No-load loss (W) |
Load loss (w) |
No-load current (%) |
Short circuit impedance (%) |
||
High pressure |
High pressure tap range (%) |
Low ressure (kV) |
||||||
30 |
20 22 24 |
±2×2.5 ±5 |
0.4 |
Dyn11 Yzn11 Yyno |
80 |
690/660 |
2.1 |
5.5 |
50 |
100 |
1010/960 |
2 |
|||||
63 |
110 |
1200/1150 |
1.9 |
|||||
80 |
130 |
1440/1370 |
1.8 |
|||||
100 |
150 |
1730/1650 |
1.6 |
|||||
125 |
170 |
2080/1980 |
1.5 |
|||||
160 |
200 |
2540/2420 |
1.4 |
|||||
200 |
240 |
3000/2860 |
1.3 |
|||||
250 |
290 |
3520/3350 |
1.20 |
|||||
315 |
340 |
4210/4010 |
1.10 |
|||||
400 |
410 |
4970/4730 |
100 |
|||||
500 |
480 |
5940/5660 |
1.00 |
|||||
630 |
570 |
6820 |
0.90 |
6.0 |
||||
800 |
700 |
8250 |
0.80 |
|||||
1000 |
830 |
11330 |
0.70 |
|||||
1250 |
970 |
13200 |
0.70 |
|||||
1600 |
1170 |
15950 |
0.60 |
|||||
2000 |
1550 |
19140 |
0.60 |
|||||
2500 |
1830 |
22220 |
0.50 |
S13-M series of 35 kv three-phase double winding non-field excitation changer distribution transformer
Rated capacity(kVA) |
Voltage Combinationand Tap range |
Vector Group Symbol |
No-load loss (W) |
Load loss (w) |
No-load current (%) |
Short circuit impedance (%) |
||
High pressure |
High pressure tap range (%) |
Low ressure (kV) |
||||||
50 |
35 38.5 |
±2×2.5 ±5 |
0.4 |
Dyn11 Yyn0 |
130 |
1200/1140 |
1.05 |
6.5 |
100 |
185 |
2010/1910 |
0.90 |
|||||
125 |
215 |
2370/2260 |
0.90 |
|||||
160 |
225 |
2820/2680 |
0.80 |
|||||
200 |
270 |
3320/3160 |
0.80 |
|||||
250 |
320 |
3950/3760 |
0.75 |
|||||
315 |
380 |
4750/4530 |
0.75 |
|||||
400 |
460 |
5740/5470 |
0.65 |
|||||
500 |
540 |
6910/6580 |
0.65 |
|||||
630 |
660 |
7860 |
0.50 |
|||||
800 |
780 |
9400 |
0.50 |
|||||
1000 |
920 |
11500 |
0.50 |
|||||
1250 |
1120 |
13900 |
0.45 |
|||||
1600 |
1350 |
16600 |
0.45 |
|||||
2000 |
1590 |
19700 |
0.40 |
|||||
2500 |
1890 |
23200 |
0.40 |
Note: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
Product detail pictures:
Related Product Guide:
Cooperation
No matter new shopper or old customer, We believe in very long expression and dependable relationship for Special Design for 500kva Oil Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian , The product will supply to all over the world, such as: South Africa , Karachi , Casablanca , In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.
By Elsa from Boston - 2018.06.28 19:27
The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
By Darlene from Kenya - 2018.06.19 10:42